Jun 14, 2016
Arbitrary Lagrangian – Eulerian (ALE) methodology has been used in Fluid – Structure Interaction (FSI) analyses with LS-DYNA® for a variety of problems. Validation of ALE solutions by comparison with experimental data provides assurance that the solutions...
Jun 1, 2016
Peach Bottom Atomic Power Station Structural Response Analysis Advanced seismic structural analysis of a multi-unit reactor building complex using High Performance Computing and SC-SASSI PROJECT TYPE Seismic Probabilistic Risk Assessment Structure Response...
Feb 14, 2016
The safety related structures in nuclear power plants often need to be designed to withstand the effects of tornado generated missile impacts. The heaviest missile to consider is often an automobile which is a soft missile due to its large deformations during the...
Dec 3, 2015
Attending an invitation from the Mexican Society of Geotechnical Engineering (SMIG), the Mexican Society of Structural Engineering (SMIE) and the Mexican Society for Earthquake Engineering (SMIS), Julio Garcia of SC Solutions presented a lecture on the topic: Seismic...
Nov 1, 2015
Pilgrim Nuclear Power Station Seismic Analysis Probabilistic soil-structural interaction analysis for detailed seismic risk assessment of power plant PROJECT TYPE Seismic Probabilistic Risk Assessment Soil-Structure Interaction Analysis LOCATION...